Fluorescent Universal Human IgG/IgM Lateral Flow Serology Kit (Quantum Dots)

$300.00

Antibody tests are a method of choice to determine if a person has been exposed to a pathogen or not. They are also incredibly valuable in the detection of autoantibodies that can be found in human autoimmune disorders. In this test, a biotinylated antigen (User supplied) is mixed with a biotinylated rabbit IgG (bind to goat anti rabbit control line) and sample (human sera or plasma) is simply mixed into with the specially designed assay running buffer in a well of the supplied 96-well plate, mixed and is then added to the sample port of the cassette. Generally, the reaction is complete in 10-15 minutes. It is very important to note that the relative stoichiometry between the biotinylated antigen, biotinylated rabbit IgG added, and the streptavidin gold is critical for assay optimization. The appropriate concentration of biotinylated antigen to use with strips is dependent upon the purity and sequence and a standard curve can be used to determine the relative ratio (generally between 1ng-100ng per test). A positive control line (biotin-rabbit IgG) antibody will bind to the goat anti rabbit (GAR) line on the test to ensure the assay is running appropriately.

300300
Cassetted Strips
CO2022-02 lateral flow cassettes. The kit ships with bare dipsticks; add cassettes if you want your strips housed in a plastic cassette with a sample well and read window. Useful for easier handling, field testing, demos, or prototyping a finished test format.
$100.00

Bare lateral flow dipstick next to a CO2022-02 plastic lateral flow cassette with sample well and read window

Left: bare dipstick (included in kit). Right: CO2022-02 cassette (this add-on).

Addons Price: $0.00
Total Price: $300.00
- +

The Attogene Fluorescent Universal Human IgG/IgM Lateral Flow Serology Kit (Quantum Dots), AU2044-01, is a fluorescent IgG IgM serology kit for developing rapid tests that detect human IgG and IgM antibodies against any antigen you can biotinylate, such as a viral antigen or an autoimmune antigen. Each kit includes 50 ready-to-use lateral flow dipsticks, 10 mL of assay running buffer, biotinylated rabbit IgG for the control line, biotinylated human IgG and IgM controls, and a 96-well plate.

The strips use biotin-binding quantum dot particles to capture your biotinylated antigen. Results are read by eye with an ultraviolet flashlight or photographed in a fluorescent strip reader, and a run is generally complete in 10 to 15 minutes.

Key Features

  • Bring your own antigen: Works with any user-supplied biotinylated antigen, so one strip format can screen many targets.
  • Separate IgG and IgM lines: Mouse anti-human IgG and mouse anti-human IgM capture lines report each antibody class.
  • Built-in run control: Biotinylated rabbit IgG binds the goat anti-rabbit (GAR) control line to confirm the strip ran correctly.
  • No striping required: Capture lines are pre-sprayed, so there is no need to stripe capture antibodies.
  • Fast fluorescent readout: 10 to 15 minute runs read with a UV flashlight or fluorescent reader.
  • Cost-effective feasibility testing: Screen antigens and conditions before investing in downstream lateral flow development.

What’s in the Fluorescent IgG IgM Serology Kit

Each fluorescent IgG IgM serology kit includes:

  • 50 lateral flow dipsticks (room temperature)
  • 10 mL Assay Running Buffer (room temperature)
  • 150 µL Biotin Rabbit IgG, control line antigen at 1 ng/µL (refrigerate)
  • 15 µL Biotin Human IgG, IgG control (refrigerate)
  • 15 µL Biotin Human IgM, IgM control (refrigerate)
  • One 96-well plate and manual

Store the kit at 2 °C to 30 °C. Strips are packaged in a vial with desiccant; avoid leaving the vial open for long periods.

You will also need: your biotinylated antigen(s), samples (contrived sample, human serum or plasma), a centrifuge for preparing clear specimens, and a pipettor with tips.

Who It’s For

Antibody tests are a method of choice for determining whether a person has been exposed to a pathogen, and they are valuable for detecting autoantibodies found in human autoimmune disorders. This kit is built for research labs and assay developers who want to check the feasibility of a serology lateral flow assay for a new antigen quickly, without building custom strips. It is also useful for comparing antigen preparations and optimizing antigen amounts before scale-up.

How to Use the Fluorescent IgG IgM Serology Kit

First prepare serially diluted biotinylated antigen in phosphate buffered saline (for example 1 µg/mL to 1 ng/mL), and prepare your clinical research sample (human serum or plasma) or contrived sample (for example humanized IgG).

  1. Add 100 µL of Lateral Flow Running Buffer to a well of the 96-well plate.
  2. Add test line reagent: 1 to 5 µL of biotinylated antigen is a good starting point. On a first run, try large dilutions and keep the volume below 15 µL if possible. For IgG or IgM line controls, use 5 µL of the biotin human IgG or IgM control.
  3. Add control line reagent: 5 µL of biotinylated rabbit IgG (5 ng total).
  4. Add 1 to 10 µL of sample. Always run positive and negative control wells.
  5. Mix each well completely by pipetting, then place a strip in the well and run vertically.
  6. Incubate for 10 to 15 minutes, then read by eye with a UV flashlight or in a fluorescent strip reader.

Full instructions are in the AU2044-01 instruction booklet (PDF). Example data using the La (SSB) autoantigen and lupus patient serum are in the universal serology technical article (PDF).

How It Works and Reading Results

Your biotinylated antigen binds the quantum dot conjugate on the strip. If the sample contains human antibodies that recognize the antigen, those antibodies are captured at the anti-human IgG and/or anti-human IgM test lines, carrying the fluorescent particles with them. Biotinylated rabbit IgG is captured at the GAR control line.

The higher the concentration of reactive human IgG or IgM, the brighter the test line compared with a strip run without sample. Unlike nucleic acid universal strips, the control line intensity does not decrease as the test lines increase. Read strips at the recommended time, since line intensity can vary with drying time.

The balance between biotinylated antigen, biotinylated rabbit IgG and the conjugate is critical. The best antigen amount depends on its purity and is generally between 1 ng and 100 ng per test; a standard curve helps find it. If no test line appears, a serial dilution may be needed because of the hook effect.

Frequently Asked Questions

What antigen do I need to supply?

Any antigen that can be biotinylated, such as a viral protein, autoantigen or allergen. The fluorescent IgG IgM serology kit does not include antigen.

What samples can I test?

Human serum or plasma, or contrived samples such as humanized IgG. Start with 1 to 10 µL per well.

How do I read the strips?

By eye under an ultraviolet flashlight, or with a fluorescent lateral flow reader for numerical readings.

Is there a colloidal gold version?

Yes. The Universal Human IgG/IgM Lateral Flow Assay Kit uses a visible gold readout, and a europium version of this fluorescent IgG IgM serology kit is also available.

Can Attogene help build a finished test?

Yes. For nucleic acid targets see the Fluorescent Universal Lateral Flow Assay Kit, and for complete projects see our custom lateral flow assay development services.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.